4
Welcome
Congratulations on purchasing your Yeoman CL Boiler, if
installed correctly Yeoman hope it will give you many years
of warmth and pleasure for which it was designed.
The purpose of this manual is to familiarise you with your
appliance, and give guidelines for its installation, operation and
maintenance. If, after reading, you need further information,
please do not hesitate to contact your Yeoman retailer.
1. General Points
IMPORTANT - DO NOT RUN THIS APPLIANCE
WITHOUT ANY WATER IN THE SYSTEM OR IF IT
IS SUSPECTED THE PIPES ARE FROZEN
1.1 Before installation and/or use of this appliance please read
these instructions fully and carefully to ensure that you have
fully understood their requirements.
The appliance must be fitted by a registered installer*,
or approved by your local building control officer.
1.2 All local regulations, including those referring to national
and European Standards need to be complied with when
installing the appliance.
1.3 Only use for domestic heating. To achieve the optimum
performance from this appliance it must be installed and
operated according to these instructions burning the fuels
recommended.
1.4 You must burn only approved fuels. Do not use with liquid
fuels or as an incinerator.
1.5 Appliance surfaces become very hot when in use. Use
a suitable fireguard
‡
if young children, elderly or infirm
persons are present.
Yeoman offer firescreens, sparkguards and hearthgate
systems for protection. Your Yeoman Retailer can advise
you about these products.
1.6 Donotplacephotographs,TV’s,paintings,porcelainor
other combustible items on the wall or near the appliance.
Exposure to hot temperatures will cause damage. Do not
place furniture or other items such as drying clothing closer
than 1m from the front of this appliance.
WARNING: Extra fuel should not be stored on or next to the
appliance. Only keep enough fuel for immediate use nearby
and never leave the appliance unattended for long periods
with any combustible material in close proximity.
1.7 Extractor fans or cooker hoods must not be placed in the
same room or space as this can cause appliance to emit
fumes into the room.
1.8 Do not obstruct inside or outside ventilation required for the
safe use of this appliance.
1.9 Do not make unauthorised changes to the appliance.
1.10 The chimney must be swept at least once a year.
See Section 13.
1.11 Do not connect, or share, the same flue or chimney system
with another appliance.
1.12 This appliance is designed to be used with the doors shut.
THERMOSTAT
This appliance is designed to be controlled by a
thermostat which regulates the rate fuel is burnt
and the amount of heat produced to hot water.
A trial and error approach will establish settings to
suit personal preference.
For Installation details refer to the instructions
(PM747) supplied with the thermostat kit.
The thermostat controls the Primary Air into the
appliance. The Primary Air Controls must be closed
in order for the thermostat to operate correctly and
efficiently.
The Primary Air Controls should only be used for
short periods during initial lighting if required.
SERIAL NUMBER
1.13 This number is required when ordering spare parts or
making warranty claims. It is found on the appliance data
plate.
The data plate is found on a swing out data plate located on
the back of the appliance on the left hand side, see Diagram 1.
Data Plate
1
1.14 This appliance gives out its heat in two ways:
—Directly into the room in which it is fitted through
convection and radiation.
—Hot water to heat radiators and domestic hot water.
The output to hot water varies depending on how quickly
the fuel is being burnt. For more detail see the graph on
page 18.
Getting Started
‡
In the U.K. these products must conform to the
latest edition of BS 8423, Fireguards for use with
solid fuel appliances.
If appliance is operating unattended they must
conform to the latest edition of BS 3248
*
Registered on the Competent Persons Scheme
(GB only see page 39/ INFO (Republic of Ireland).