22
INSTALLATION INSTRUCTIONS
INSTALLATION
Flue and Appliance Fixings
4.34 Pull appliance and flue assembly away from the hearth.
4.35 Drill four fixing holes for the wall plate and insert
wall plugs supplied.
4.36 Put the horizontal flue onto the elbow and reposition the
appliance.
4.37 Check the flue runs smoothly through the wall.
4.38 Fix the wall plate to the wall using the four black screws
provided.
4.39 Drill through the fixing tab of the wall plate using a
3.5mm drill.
4.40 Secure with the screw provided.
4.41 Make good and weatherproof around the outside of the
flue.
4C. TOP EXIT – VERTICAL FLUE
4.42 Where a vertical only flue system has been purchased, refer
to Installation & Instructions, Site Requirements, Section 3D.
4.43 Pay careful attention to the following:
Terminal positions
Flue supports
Weatherproofing
Fire precautions
4.44 Local and national codes of practice must be followed for
all the above.
4.45 A restrictor must be fitted with vertical flues. See chart
below for restrictor sizes.
PLEASE NOTE: When installing the appliance in
conjunction with a vertical termination kit, there is a
unique kit for use with this appliance (Yeoman Part No.
999-539). This kit differs in that it has restrictors with
sliding plates. Please ensure you have the correct kit
before proceeding with the installation.
Vertical Height from Appliance Restrictor Size
3000mm to 4990mm 52mm ø (Sliding)
5000mm to 10000mm 40mm ø (Sliding)
4.46 It is important that the sliding restrictor assembly is used.
The restrictor assembly must be fitted with the slide collars
uppermost and the top restrictor plate must be checked to
ensure it moves freely before the flue is fitted.
AR2396
12
Restrictor assembly
Slide collars
4.47 Flue Lengths over 5m (Midi Top Exit Only)
If the flue length extends 5m above the appliance a 40mm
Ø restrictor must be fitted. This restrictor can be found in
the appliance packing kit supplied.
4.48 To fit the restrictor undo the bolts on the slide collars on the
restrictor assembly, see Diagram 13.
AR2396a
Restrictor
plate
Screws
13
4.49 Remove the restrictor plate that is current in place and fit
the 40mm Ø one from the kit.
Secure with the screws and ensure that the plate moves
freely up and down on the slide collars.
4.50 Fit the restrictor assembly as previous described.
PURGE THE SUPPLY PIPE
This is essential to expel any debris that may block the gas
controls.
4.51 Connect the gas to the 8mm elbow on the rear of the
appliance, See Diagram 14.